Double Duece

Physical Specs
'Modeled' Electrolyzer Design: 
Generic series cell
Electrode Material: 
316L
Electrode Type: 
Plates
Number of Electrodes: 
8
Number of Cells: 
4
Electrolyte: 
KOH
Electrolyzer Design Modifications: 

28 3"x6" stainless steel plates, 7 plates used in each series cell, then connected in series in pairs. 1/8 in. gaping in plates, plates are 1/8 thick. configured +nnnnn--nnnnn+. usied tool dip to insulate straps, and wrapped cells with pvc shrink wrap(not shown in pic).

Stats
LPM: 
0.01
Volts: 
13.4
Starting Amps: 
19
Amps when hot: 
24
Peak Temperature: 
90-110F running for an 1:45:00 (this was a guess by feeling container)
Overall Design
Project Status: 
Testing
Electrolyzer Problems: 

leaked fixed

Final Electrolyzer Notes: 

using 2tbs of KoH in each container with approx. 3/4gal. distilled water each.

Click the images below for bigger versions:
Were Images Uploaded?: 
Yes
Syndicate content