'Modeled' Electrolyzer Design:
Electrolyzer Design Modifications:
Single plates; plate arrangement: (+) N N N N N (-) N N N N N (+); plate size: 8.50" x 2.50" x .035"; plates ultrasonically cleaned in 10% electrolyte solution after sanding, magnetically orientated, pickled, and then conditioned for 24 hours; plate stack encased with peek sheets on all four sides; peek sheets on botton & top with 1/2 opening on top center & bottom center
Impressive
Nice,
Looks like you were very precise and thorough.
I'd never heard of pickling metal before (only eggs and veggies)
. I had to look it up.
Why did you go with the 10% KOH solution as opposed to the 28% (by weight) that seems to be the standard?
-Peter
When cleaning, a strong
When cleaning, a strong solution is not necessary, especially when using an ultrasonic cleaner. The conditioning solution was the defacto standard.
Patrick
OK, the way the sentence was
OK, the way the sentence was structured, it looks like you used 10% for conditioning also.
In case anyone wants to know where I'm getting the 28%, look in Here.